 Low-Voltage, 0.5C Accuracy Digital Thermometer and Thermostat
www.maxim-ic.com
DS620
GENERAL DESCRIPTION
The DS620 digital thermometer and thermostat provides low-voltage (1.7V VDD 3.5V) temperature measurements with 0.5C accuracy from 0C to +70C and an operating temperature range of -55C to +125C. The DS620 communicates over a 2-wire digital interface. For distributed-sensing applications, it is multidroppable with three address pins that allow up to eight DS620s to operate on a single bus. The DS620 has thermostat functionality with userdefined thresholds stored in EEPROM registers, and it can be configured for standalone thermostat operation. The programmable output (PO) pin serves as the thermostat output, and this pin can also be configured to function as an active-low control for peripheral devices.

FEATURES
Low-Voltage Operation: 1.7V to 3.5V 0.5C Accuracy from 0C to +70C Operating Temperature Range: -55C to +125C (-67F to +257F) Temperature Measurements Require No External Components Resolution is User-Selectable to 10-, 11-, 12-, or 13-Bits (0.5C, 0.25C, 0.125C, and 0.0625C LSb Weight, Respectively) Multidroppable Fast (200ms max) Temperature-to-Digital Conversion Time Thermostatic Settings are User-Definable and Nonvolatile Standalone Thermostat Capability Data is Read/Written Through a 2-Wire Serial Interface Package: 8-Pin mSOP
APPLICATIONS
Portable Applications Low-Voltage Temperature-Sensitive Applications Computers/Servers Test Equipment Medical Instruments Industrial Applications
ORDERING INFORMATION
PART DS620U DS620U/T&R TEMP RANGE -55C to +125C -55C to +125C PIN-PACKAGE 8 SOP, Exposed Pad 8 SOP Exposed Pad Tape-and-Reel
TYPICAL OPERATING CIRCUIT
1.7V to 3.5V 1.7V to 3.5V
PIN CONFIGURATION
DS620 SDA
SDA SCL VDD SDA SCL PO DS620 A0 A1 A2 GND
1 2 3 4
8 7 6 5
VDD A0 A1 A2
SCL PO
Thermostat
HOST
GND
8-Pin mSOP Package
Exposed Pad
Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device may be simultaneously available through various sales channels. For information about device errata, click here: www.maxim-ic.com/errata.
1 of 15
081004
DS620 Digital Thermometer and Thermostat
PIN DESCRIPTION
PIN 1 2 3 4 5 6 7 8 NAME SDA SCL PO GND A2 A1 A0 VDD FUNCTION
Data Input/Output Pin for serial communication. Open drain. (No diode connection to VDD). Clock Input Pin for 2-wire serial communication. Programmable Output Pin. Open drain. (No diode connection to VDD). Ground Pin. Address Input Pin. Address Input Pin. Also serves as an input to trigger one-shot conversions during standalone use. Address Input Pin. Supply Voltage Pin. +1.7V to +3.5V power supply pin.
Figure 1. Block Diagram
DS620
Temp. Core Digital Control Bandgap POR ADC
Memory Array Configuration Register Conversion Control TH, TL Registers Digital Comparator Temperature Register Address Counter Temperature Counter User EEPROM Registers SCL SDA 2-Wire Interface Memory Interface Logic Charge Pump PO Pin Control PO
Address/Command Decode
A2 A1
A0
2 of 15
DS620 Digital Thermometer and Thermostat
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin, Relative to Ground Operating Temperature Range Storage Temperature Range Soldering Temperature ESD rating on all pins -0.5V to +4.5V -55C to +125C -55C to +125C See IPC/JEDEC J-STD-020A Specification 4KV HBM
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device.
RECOMMENDED DC OPERATING CONDITIONS
(3.5V VDD 1.7V, TA = -55C to +125C.) PARAMETER Voltage Range on Any Pin, Relative to Ground Supply Voltage for EEPROM Writes SYMBOL VDD VDD CONDITIONS (Note 1) (Note 1) MIN 1.7 2.0 TYP MAX 3.5 3.5 UNITS V V
DC ELECTRICAL CHARACTERISTICS
(3.5V VDD 1.7V, TA = -55C to +125C.) PARAMETER Thermometer Error Input Logic High Input Logic Low SDA Output Logic Low Voltage PO Saturation Voltage Input Current for each I/O pin I/O Capacitance Standby Current SYMBOL TERR VIH VIL VOL1 VOL2 VOL CI/O ISTBY CONDITIONS 0C to +70C -55C to +125C (Note 1) (Note 1) 3mA sink current (Note 1) 6mA sink current (Note 1) 4mA sink current (Note 1) 0.4 < VI/O < 0.9 x VDD 0C to +70C (Note 2) Temperature conversion, 55C to +85C (Note 3) Temperature conversion, +85C to +125C (Note 3) 2 E write (Note 3) 10 bit 11 bit 12 bit 13 bit 0.7 x VDD - 0.5 0 0 0 -10 MIN TYP MAX 0.5 2 VDD + 0.5 0.3 x VDD 0.4 0.6 0.4 +10 10 2 800 A 900 500 25 50 100 200 A ms UNITS C V V V V A pF A
Active Supply Current
IDD
Temperature Conversion Time
TTC
Note 1: All voltages are referenced to GND. Note 2: Specified with SDA = VDD; A0, A1, A2 = 0V or VDD. Note 3: Specified with A0, A1, A2 = 0V or VDD.
3 of 15
DS620 Digital Thermometer and Thermostat
AC ELECTRICAL CHARACTERISTICS
EEPROM AC Electrical Characteristics PARAMETER EEPROM Write Cycle Time EEPROM Writes EEPROM Data Retention SYMBOL TWR NEEWR tEEDR CONDITIONS -40C to +85C -40C TA +85C (Note 1) TA = +25C (Note 1) -40C to +125C (Note 2) MIN 10k 40k 10 TYP 20k 80k years MAX 10 UNITS ms writes
2-Wire AC Electrical Characteristics PARAMETER SCL Frequency Bus Free Time Between a STOP and START Condition START and Repeat START Hold Time from Falling SCL Low Period of SCL High Period of SCL Repeated START Condition Setup Time to Rising SCL Data-Out Hold Time from Falling SCL Data-In Setup Time to Rising SCL Rise Time of SDA and SCL Fall Time of SDA and SCL STOP Setup Time to Rising SCL Capacitive Load for Each BUS Line Input Capacitance Spike Pulse Width that can be Suppressed by Input Filter SYMBOL fSCL tBUF tHD:STA tLOW tHIGH tSU:STA tHD:DAT tSU:DAT tR tF TSU:STO CB CI 0 10 50 (Note 3, 4) (Note 3) (Note 3) (Note 3) (Note 3) (Note 3) (Note 3, 5) (Note 3, 5) CONDITIONS MIN 0 1.3 0.6 1.3 0.6 0.6 0 100 20 + 0.1xCB 20 + 0.1xCB 0.6 400 1000 300 0.9 TYP MAX 400 UNITS KHz s s s s s s ns ns ns s pF pF ns
Note 1: VDD must be 2.0V to 3.5V. Note 2: Write done at 25C. Note 3: All values referenced to 0.9 VDD and 0.1 VDD. Note 4: After this period the first clock pulse is generated. Note 5: For example, if CB = 300pF, then tR(MIN) = tF(MIN) = 50ns.
4 of 15
DS620 Digital Thermometer and Thermostat
Figure 2. Timing Diagram
Table 1. Register Summary Parameter
TH and TL Registers Size: 2-Bytes Note that the 3 LSbs are always "don't cares" for writes (i.e., they are not saved) and always read out as 0s. Configuration Register Size: 2-Bytes Temperature Register Size: 2-Bytes
Information
EEPROM Factory State: TH = 15C (0000 0111 1000 0000) [0780h] TL = 10C (0000 0101 0000 0000) [0500h] SRAM and EEPROM. See Figure 4 and Table 5 for detailed information and power-up/factory state. SRAM Power-Up State: -60C (1110 0010 0000 0000) [E200h]
TEMPERATURE MEASUREMENT
The DS620 measures temperature using a bandgap-based temperature sensor. A delta-sigma, analog-to-digital converter (ADC) converts measured temperature to a 10-, 11-, 12-, or 13-bit (user-selectable) digital value that is calibrated in C; for F applications, a lookup table or conversion routine must be used. Throughout this data sheet, the term "conversion" is used to refer to the entire temperature measurement and ADC sequence. The DS620 can be configured to power up either automatically converting temperature or in a low-power standby state. The preferred power-up mode can be set using the AUTOC bit in the configuration register as explained in the Configuration Register section of this data sheet. The DS620 can be programmed to perform continuous consecutive conversions (continuous conversion mode) or to perform single conversions on command (one-shot mode). The conversion mode is programmed through the 1SHOT bit in the configuration register as explained in the Configuration Register section of this data sheet. In continuous conversion mode, conversions are performed after a Start Convert command is issued (or upon powerup if the AUTOC bit in the configuration register is set to 1) until a Stop Convert command is issued, at which time the device goes into a low-power standby state. Continuous conversions can be restarted at any time using the Start Convert command. In one-shot mode, the DS620 performs a single temperature conversion either at powerup (if AUTOC = 1) or when a Start Convert command is issued (if AUTOC = 0). When the conversion is complete,
5 of 15
DS620 Digital Thermometer and Thermostat the device enters a low-power standby state and remains in that state until a temperature conversion is again initiated by a Start Convert command. The R0 and R1 bits in the configuration register allow the user to set the conversion resolution to be 10, 11, 12, or 13 bits (0.5C, 0.25C, 0.125C, and 0.0625C LSb weight, respectively) as shown in Table 6. The default resolution at power-up is 13-bits. Note that the conversion time doubles for each additional bit of resolution. After each conversion, the digital temperature is stored as a 16-bit two's complement number in the 2-byte temperature register as shown in Figure 3. The temperature register is located in address spaces AAh (MSB) and ABh (LSB) of the DS620 memory. The sign bit (S) indicates if the temperature is positive (S = 0) or negative (S = 1). Bits 2, 1, and 0 of the temperature register are hardwired to 0. When the device is configured for 13-bit resolution, the 13 MSbs (bits 15 through 3) of the temperature register will contain temperature data. For 12-bit resolution, the 12 MSbs (bits 15 through 4) of the temperature register will contain data, and bit 3 will be 0. Likewise, for 11-bit resolution, the 11 MSbs (bits 15 through 5) will contain data, and for 10-bit the 10 MSbs (bits 15 through 6) will contain data, and all unused LSbs will contain 0s. Table 2 gives examples of 13-bit resolution output data and the corresponding temperatures.
Figure 3. Temperature, TH, And TL Register Format
bit 15 bit 14 bit 13 Bit 12 bit 11 bit 10 bit 9 bit 8
MS Byte LS Byte
S
bit 7
27
bit 6
26
bit 5
25
Bit 4
24
bit 3
23
bit 2
22
bit 1
21
bit 0
2
0
2
-1
2
-2
2
-3
2
-4
0
0
0
Table 2. 13-Bit Resolution Temperature/Data Relationship
Temperature (C) +125 +25.0625 +10.125 +0.5 0 -0.5 -10.125 -25.0625 -55 Digital Output (binary) 0011 1110 1000 0000 0000 1100 1000 1000 0000 0101 0001 0000 0000 0000 0100 0000 0000 0000 0000 0000 1111 1111 1100 0000 1111 1010 1111 0000 1111 0011 0111 1000 1110 0100 1000 0000 Digital Output (hex) 3E80h 0C88h 0510h 0040h 0000h FFC0h FAF0h F378h E480h
WRITING TO THE TEMPERATURE REGISTER
The user is given access to write to the DS620 temperature register. This feature can be used for system test and debugging by allowing the user to force the temperature reading above or below fault thresholds without having to heat or cool the device. If data is written to the temperature register while conversions are in progress, the result of the next completed conversion will overwrite any data that was written to the temperature register. Additionally, no update of the flag bits in the configuration register, nor an update of the PO pin occur as a result of the temperature being written if a conversion is taking place. To avoid this from happening, conversions should first be stopped before writing to the temperature register. When writing to the temperature register, both the MSB and the LSB should be written. An update of the flag bits and PO pin will only occur after the LSB has been written. See Writing to the DS620 for more information.
6 of 15
DS620 Digital Thermometer and Thermostat
THERMOSTAT OPERATION
The PO pin on the DS620 operates as the thermostat output when it is configured as PO-HIGH or PO-LOW through the P01 and P02 bits of the configuration register. In both of these configurations, PO is updated after every temperature conversion or write to the temperature register, and remains at the updated value until the next conversion or write completes. PO-HIGH and PO-LOW are active-low and are activated and deactivated based on user-defined upper and lower trip-points. PO-HIGH is activated when the measured temperature meets or exceeds the value stored in the upper trip-point register (TH), and stays active until the temperature meets or falls below the value stored in the lower trip-point register (TL) (see Figure 4a). This allows the user to program any amount of hysteresis into the output response. Similarly, PO-LOW is activated when the measured temperature meets or goes below the value stored in the low trip-point register (TL), and stays active until the temperature meets or exceeds the value stored in the upper trip-point register (TH) (see Figure 4b). The TH register is located in address spaces A0h (MSB) and A1h (LSB) and the TL register is located in address spaces A2h (MSB) and A3h (LSB) of the DS620 memory. The TH and TL registers (see Table 1) contain centigrade temperature values in two's complement format and are stored in EEPROM; therefore, they are nonvolatile (NV) and can be programmed prior to installation of the DS620 for use in standalone applications. All bits in the TH and TL registers are used in the comparison to the temperature value in the temperature register for the thermostat operation, regardless of the number of bits used for the temperature conversions as decided by the R0 and R1 bits in the configuration register. Therefore, to ensure proper thermostat operation, any bits not used for the temperature measurement should be set to 0 in the TH and TL registers. For example, for 11-bit temperature conversions, bits 3 and 4 in the TH and TL register should be set to 0 prior to comparison to the measured temperature. (Bits 0 to 2 are automatically set to 0). Another thermostat feature is the temperature high and low flags (THF and TLF) in the configuration register. These bits provide a record of whether the temperature has ever been equal to or greater than TH or equal to or less than TL at anytime since power up or since the bits were last cleared. If the temperature ever meets or exceeds the TH register value, the THF bit in the configuration register is set to 1, and if the temperature ever meets or falls below the TL value, the TLF bit in the configuration register is set to 1. Once THF or TLF has been set, it remains set until the power is cycled or it is overwritten with a 0 by the user.
Figure 4. Thermostat Operation
a) PO-high Logic 1 b) PO-low Logic 1
Logic 0 TL TH
Tem Temp p
Logic 0 TL TH
Tem Temp p
STANDALONE THERMOSTAT OPERATION
The DS620 can function as a standalone thermostat, i.e., it can provide thermostat functionality without requiring communication with a microcontroller. For standalone thermostat operation, the TH, TL, and configuration registers must be programmed to the desired values prior to installation. For standalone operation, the AUTOC bit in the configuration register must be set to 1 so that measurements begins automatically at power up. This also configures the A1 pin as an input pin that can trigger a conversion. In addition, PO must be configured as PO-HIGH or PO-LOW . The 1SHOT bit in the configuration register is used to enable the DS620 to perform continuous conversions at power up (1SHOT = 0) or a single conversion (one-shot) at power up or upon request (1SHOT = 1). In one-shot mode, one conversion is performed at power-up and then the device enters a low-power standby state until A1 is toggled high. The A1 pin must be toggled low and back high again to start another conversion.
7 of 15
DS620 Digital Thermometer and Thermostat
PO PIN
The PO pin is a user-programmable open-drain output, which is configured through the PO1 and PO2 bits in the configuration register. PO can operate as a thermostat output (PO-HIGH or PO-LOW), or it can be forced low for control of peripheral devices. When PO is configured as PO-HIGH or PO-LOW , this pin operates as described in the Thermostat Operation section. This pin can be reconfigured at anytime to switch between functions. Table 3 defines the various configuration options for this pin.
Table 3. PO Configuration
Function Thermostat Output (PO-high) Thermostat Output (PO-low) Force PO Low PO2 1 1 0 PO1 1 0 X
EEPROM REGISTERS AND MEMORY MAP
The DS620 has a 14-byte linear address space with registers for temperature, thermostat thresholds, and control as well as four bytes of user EEPROM for general use. All address space is shadowed by RAM. The DS620 Memory Map is shown in Table 4. See the Writing to the DS620 and the Reading from the DS620 sections for details in writing to and reading from the DS620 EEPROM registers and memory map.
Table 4. Memory Map
Address (hex) A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD Description TH MSB TH LSB TL MSB TL LSB User User User User Undefined Undefined Temperature MSB Temperature LSB Configuration MSB Configuration LSB
CONFIGURATION REGISTER
The configuration register allows the user to program various DS620 options such as conversion resolution, operating mode, and thermostat capability. It also provides information to the user about conversion status, EEPROM activity, device address, and thermostat activity. The configuration register is arranged as shown in Figure 5 and detailed descriptions of each bit are provided in Table 5. It is located in address spaces ACh (MSB) and ADh (LSB) in the DS620 memory. Note that the R0, R1, AUTOC, 1SHOT, and PO1 bits are stored in EEPROM so they can be programmed prior to installation if desired. All other configuration bits are SRAM and power up in the state shown in Table 5.
8 of 15
DS620 Digital Thermometer and Thermostat
Figure 5. Configuration Register Address ACh
bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8
*
MS Byte
DONE
NVB
THF
TLF
R1
*
R0
*
AUTOC
1SHOT
*
Address ADh
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
LS Byte
*
PO2
PO1*
A2
A1
A0
M*
M*
M*
Stored in EEPROM
Table 5. Configuration Register Bit Descriptions
Bit Name DONE NVB User Access Read Only Read Only Functional Description At power-up, DONE = 1. (Unless AUTOC = 1) DONE = 0--Temperature conversion is in progress. DONE = 1--Temperature conversion is complete. At power-up, NVB = 0 2 NVB = 1--Write to an E memory cell is in progress NVB = 0--Nonvolatile memory is not busy. At power-up, THF = 0 THF = 1--The measured temperature has reached or exceeded the value stored in the TH register at anytime since power-up or since the bit was last cleared. THF remains a 1 until the power is cycled or it is overwritten with a 0 by the user. At power-up, TLF = 0 TLF = 1--The measured temperature has met or fallen below the value stored in the TL register at anytime since power-up or since the bit was last cleared. TLF remains a 1 until the power is cycled or it is overwritten with a 0 by the user. Used to set conversion resolution (see Table 6). Factory state = 1 Used to set conversion resolution (see Table 6). Factory state = 1 Determines whether the DS620 powers up idle or converting. Factory state = 0 AUTOC = 1--DS620 powers-up converting temperature. AUTOC = 0--DS620 powers-up idle. Configures temperature conversion mode. Factory state = 0 1SHOT = 1: One-shot mode For AUTOC = 0, the device powers up idle The Start Convert command causes a single temperature conversion and then the device returns to a low-power standby state. If AUTOC = 1, the A1 pin is reconfigured as a conversion trigger for standalone operation and the device powers up and performs 1 conversion. Single conversions can be initiated using the Start Convert command or by toggling A1 high. 1SHOT = 0: Continuous conversion mode For AUTOC = 0, the Start Convert command initiates continuous conversions. For AUTOC = 1, the device powers up performing continuous conversions. Note: Changing the 1SHOT bit to 1 while continuous conversions are in progress does not stop the conversions. A Stop Convert command must first be issued after which one-shot 9 of 15
THF
Read/Write
TLF
Read/Write
R1 R0
* *
Read/Write Read/Write
AUTOC
*
Read/Write
1SHOT
*
Read/Write
DS620 Digital Thermometer and Thermostat conversions can be performed. See Writing the 1SHOT Bit Command Sequence section for writing more information on writing the 1SHOT bit. At power-up, PO2 = 1. PO2 = 0 forces the PO pin low (see Table 3) PO2 = 1 configures PO as the thermostat output (PO-HIGH or PO-LOW , as determined by PO1). When PO2 = 1, PO1 configures the PO pin as either PO-HIGH or PO-LOW (see Table 3) When PO2 = 0, PO1 is a "don't care". Factory state = 0 Shows address bit A2, as determined by pin A2. Shows address bit A1, as determined by pin A1. Shows address bit A0, as determined by pin A0. User memory for general-purpose data storage.
PO2
Read/Write
PO1* A2 A1 A0 M*
Read/Write Read Only Read Only Read Only Read/Write
*
Stored in EEPROM
Table 6. Resolution Configuration
R1 0 0 1 1 R0 0 1 0 1 Resolution 10-bit 11-bit 12-bit 13-bit LSb Weight (C) 0.5 0.25 0.125 0.0625 Max Conversion Time (ms) 25 50 100 200
2-WIRE SERIAL DATA BUS
The DS620 communicates over a standard bidirectional 2-wire serial data bus that consists of a serial clock (SCL) signal and serial data (SDA) signal. The DS620 interfaces to the bus through the SCL input pin and open-drain SDA I/O pin. All communication is MSb first. The following terminology is used to describe 2-wire communication: Master Device: Microprocessor/microcontroller that controls the slave devices on the bus. The master device generates the SCL signal and START and STOP conditions. Slave: All devices on the bus other than the master. The DS620 always functions as a slave. Bus Idle or Not Busy: Both SDA and SCL remain high. SDA is held high by a pullup resistor when the bus is idle, and SCL must either be forced high by the master (if the SCL output is push-pull) or pulled high by a pullup resistor (if the SCL output is open-drain). Transmitter: A device (master or slave) that is sending data on the bus. Receiver: A device (master or slave) that is receiving data from the bus. START Condition: Signal generated by the master to indicate the beginning of a data transfer on the bus. The master generates a START condition by pulling SDA from high to low while SCL is high (see Figure 6). A "repeated" START is sometimes used at the end of a data transfer (instead of a STOP) to indicate that the master will perform another operation. STOP Condition: Signal generated by the master to indicate the end of a data transfer on the bus. The master generates a STOP condition by transitioning SDA from low to high while SCL is high (see Figure 6). After the STOP is issued, the master releases the bus to its idle state. Acknowledge (ACK): When a device (either master or slave) is acting as a receiver, it must generate an acknowledge (ACK) on the SDA line after receiving every byte of data. The receiving device performs an ACK by pulling the SDA line low for an entire SCL period (see Figure 6). During the ACK clock cycle, the transmitting device must release SDA. A variation on the ACK signal is the "not acknowledge" (NACK). When the master device
10 of 15
DS620 Digital Thermometer and Thermostat is acting as a receiver, it uses a NACK instead of an ACK after the last data byte to indicate that it is finished receiving data. The master indicates a NACK by leaving the SDA line high during the ACK clock cycle. Slave Address: Every slave device on the bus has a unique 7-bit address that allows the master to access that device. The DS620's 7-bit bus address is 1 0 0 1 A2 A1 A0, where A2, A1, and A0 are user-selectable via the corresponding input pins. The three address pins allow up to eight DS620s to be multidropped on the same bus. Control Byte: The control byte is transmitted by the master and consists of the 7-bit slave address plus a read/write (R/W bit (see Figure 7). If the master is going to read data from the slave device then R/W = 1, and if ) the master is going to write data to the slave device then R/W = 0. Address Byte: The address byte is used by the master to tell the DS620 which address location in the memory map in Table 4 is going to be accessed during communication or which command should be performed. See Command Set section.
Figure 6. START, STOP, AND ACK SIGNALS
SDA
... ...
START Condition ACK (or NACK) STOP From Receiver Condition
SCL
Figure 7. Control Byte
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
1
0
0
1
A2
A1
A0
R/W
GENERAL 2-WIRE INFORMATION
All data is transmitted MSb first over the 2-wire bus. One bit of data is transmitted on the 2-wire bus each SCL period. A pullup resistor is required on the SDA line and, when the bus is idle, both SDA and SCL must remain in a logichigh state. All bus communication must be initiated with a START condition and terminated with a STOP condition. During a START or STOP is the only time SDA is allowed to change states while SCL is high. At all other times, changes on the SDA line can only occur when SCL is low: SDA must remain stable when SCL is high. After every 8-bit (1-byte) transfer, the receiving device must answer with an ACK (or NACK), which takes one SCL period. Therefore, nine clocks are required for every one-byte data transfer.
INITIATING 2-WIRE COMMUNICATION
To initiate 2-wire communication, the master generates a START followed by a control byte containing the DS620 slave address. The R/W bit of the control byte must be a 0 (write) since the master next writes a command byte or an address byte. The DS620 responds with an ACK after receiving the control byte. This must be followed by a command byte from the master which indicates what type of command operation is to be performed, or an address byte when the master intends to write to or read from the DS620. The DS620 again responds with an ACK after receiving the command or address byte. The master can then issue a STOP to signal the end of the communication sequence, or continue writing to the address memory. See the Command Set section for details on 11 of 15
DS620 Digital Thermometer and Thermostat the DS620 commands. See Writing to the DS620 or Reading from the DS620 for more information on reading from and writing to the DS620.
WRITING TO THE DS620
The master can write data to the DS620 by issuing an address byte following the control byte. The R/W bit in the control byte must be a 0 (write). After receiving an ACK from the DS620 in response to the control byte, the master sends the address of the first register byte to be written, loading the address counter with the desired location. The DS620 responds with another ACK, after which the master sends the data to be written. After receiving each byte of data, the DS620 responds with an ACK. The master continues to write data to successive address locations until it indicates there is no more data to be written by sending a STOP or repeated START condition. The DS620 ignores any data written once the address increments past ADh, the last defined register in the DS620 memory, and indicates this by sending a NACK after each byte. It also ignores data written to undefined addresses A8h and A9h. All writes to the DS620 are made to the shadow RAM. Once data is written to the shadow RAM, it is only stored to EEPROM by issuance of a Copy Data command from the master. At that time all registers are copied to EEPROM, except the Temperature registers, which are SRAM only, and the undefined registers. The DS620 must be set to the continuous conversion mode and be actively converting temperature to enable the Copy Data command to function properly. See Copying to EEPROM Command Sequence for more information.
READING FROM THE DS620
The master can read data from the DS620 by issuing an address byte following the control byte. The R/W bit in the control byte must be a 0 (write). After receiving an ACK from the DS620 in response to the control byte, the master writes the address of the first register byte to be read, loading the address counter with the desired location. The DS620 will respond with another ACK. The master then must issue a repeated START (or a STOP and a START) followed by a control byte with the same slave address as the first control byte. However, this time the R/W bit must be a 1 which tells the DS620 that a "read" is being performed. After the DS620 sends an ACK in response to this control byte, it begins transmitting the requested data on the next clock cycle. The master responds with an ACK between each byte of data read from the DS620 until no further bytes of data are to be read, at which time the master responds with a NACK followed by a STOP. The DS620 sends all 1's (FFh) once the address increments past ADh, the last defined register in the DS620 memory. There is no guaranteed state of data read from the undefined registers, A8h and A9h. The Recall Data command should be issued before a read to assure that the contents of the EEPROM will be in the Shadow RAM when read.
COMMAND SET
The DS620 command set is detailed below: Start Convert [ 51h ] 0101 0001 Initiates temperature conversions. If the part is in one-shot mode (1SHOT = 1), only one conversion is performed. In continuous mode (1SHOT = 0), continuous temperature conversions are performed until a Stop Convert command is issued (even if 1SHOT is changed to a 1). Stop Convert [ 22h ] 0010 0010 Stops temperature conversions when the device is in continuous conversion mode (1SHOT = 0). This command has no function if the device is in one-shot mode (1SHOT = 1) Recall Data [ B8h ] 1011 1000 Refreshes SRAM shadow register with EEPROM data. Copy Data [ 48h ] 0100 1000 Copies data from all SRAM shadow registers to EEPROM. NOTE: The DS620 must be set to the continuous conversion mode and be actively converting temperature to enable the Copy Data command to function properly. See example command sequence in the Copying to EEPROM Command Sequence section for more information. Software POR [ 54h ] 0101 0100 Initiates a software power-on-reset (POR), which stops temperature conversions and resets all registers and logic to their power-up states. The software POR allows the user to simulate cycling the power without actually powering down the device. This command should not be issued while a Copy Data command is in progress.
12 of 15
DS620 Digital Thermometer and Thermostat
COPYING TO EEPROM COMMAND SEQUENCE
Data is written to DS620 and then copied from SRAM to EEPROM BUS MASTER MODE TX TX RX TX RX TX RX TX RX TX RX TX RX TX TX RX DS620 MODE RX RX TX RX TX RX TX RX TX RX TX RX TX RX RX TX DATA (MSB FIRST) START ACK A4h ACK ACK ACK ACK ACK START ACK COMMENTS Bus master initiates a START condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge bit. Bus master sends the address location of the first byte of data to be written. (In this case the first byte of user EEPROM). DS620 generates acknowledge. Bus master sends one byte of data to the SRAM location for EEPROM address A4h. DS620 generates acknowledge. Bus master sends one byte of data to the SRAM location for EEPROM for address A5h. DS620 generates acknowledge. Bus master sends one byte of data to the SRAM location for EEPROM for address A6h. DS620 generates acknowledge. Bus master sends one byte of data to the SRAM location for EEPROM for address A7h. DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Bus master sends the address location of the MSb of the configuration register (contains the 1SHOT bit). This writes to the SRAM location corresponding the EEPROM location. NOTE: Sequence numbers 17 through 23 need to be done only if DS620 is in 1SHOT mode: 1SHOT = 1. DS620 generates acknowledge. Bus master writes to the configuration register putting the DS620 in continuous conversion mode: 1SHOT = 0. DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge Master sends START CONVERT command to DS620 to start temperature conversions. DS620 generates acknowledge bit and begins conversions. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Bus master sends the address location of the MSb of the configuration register (contains the 1SHOT bit). This writes to the SRAM location corresponding the EEPROM location. NOTE: command sequence numbers 29 through 34 need only be done if a return to 1SHOT mode operation is needed. 13 of 15 SEQUENCE NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TX
RX
ACh
17
RX TX RX TX TX RX TX RX TX TX RX
TX RX TX RX RX TX RX TX RX RX TX
ACK xxxxxxx0b ACK START ACK 51h ACK START ACK
18 19 20 21 22 23 24 25 26 27 28
TX
RX
ACh
29
DS620 Digital Thermometer and Thermostat RX TX TX TX RX TX RX TX TX RX TX RX RX RX TX RX TX RX RX TX ACK xxxxxxx1b START ACK 48h ACK START ACK DS620 generates acknowledge. Bus master writes to the configuration register putting the DS620 back in 1SHOT mode: 1SHOT = 1. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Master sends COPY DATA command to DS620 to copy data in from SRAM memory to EEPROM memory. DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Bus master sends a STOP CONVERT command to stop the DS620 from continuously converting temperature. NOTE: Bus master should ensure that EEPROM copy operation is complete before executing the STOP CONVERT command by either waiting 10ms from the time of the COPY DATA command or checking the NVB bit in configuration register DS620 generates acknowledge. Bus master sends STOP condition to end communication with DS620. (The bus master could send a repeated start condition if additional communication with the DS620 is desired.) 30 31 32 33 34 35 36 37 38 39
TX
RX
22h
40
RX TX
TX RX
ACK STOP
41 42
WRITING THE 1SHOT BIT COMMAND SEQUENCE
Configuring from continuous mode to 1SHOT mode. BUS MASTER MODE TX TX RX TX RX TX TX RX TX RX TX RX TX TX RX TX DS620 MODE RX RX TX RX TX RX RX TX RX TX RX TX RX RX TX RX DATA (MSB FIRST) START ACK 51h ACK START ACK ACh ACK xxxxxxx1b ACK START ACK 48h COMMENTS Bus master initiates a START condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge bit. Master sends START CONVERT command to DS620 to start temperature conversions. DS620 generates acknowledge bit and begins conversions. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Bus master sends the address location of the MSb of the configuration register (contains the 1SHOT bit). This writes to the SRAM location corresponding the EEPROM location. DS620 generates acknowledge. Bus master writes to the configuration register putting the DS620 in 1SHOT mode: 1SHOT = 1. DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Master sends COPY DATA command to DS620 to copy data in from SRAM memory to EEPROM memory. 14 of 15 SEQUENCE NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
DS620 Digital Thermometer and Thermostat RX TX TX RX TX RX RX TX ACK START ACK DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Bus master sends STOP CONVERT command to stop the DS620 from continuously converting temperature. NOTE: Bus master should ensure that EEPROM copy operation is complete before executing the STOP CONVERT command by either waiting 10ms from the time of the COPY DATA command or checking the NVB bit in configuration register DS620 generates acknowledge. Bus master sends STOP condition to end communication with DS620. (The bus master could send a repeated start condition if additional communication with the DS620 is desired.) 17 18 19 20
TX
RX
22h
21
RX TX
TX RX
ACK STOP
22 23
Configuring from 1SHOT to mode to continuous conversion mode. BUS MASTER MODE TX TX RX TX RX TX RX TX TX RX TX RX TX TX RX TX RX TX DS620 MODE RX RX TX RX TX RX TX RX RX TX RX TX RX RX TX RX TX RX DATA (MSB FIRST) START ACK ACh ACK xxxxxxx0b ACK START ACK 51h ACK START ACK 48h ACK STOP COMMENTS Bus master initiates a START condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge bit. Bus master sends the address location of the MSb of the configuration register (contains the 1SHOT bit). This writes to the SRAM location corresponding the EEPROM location. DS620 generates acknowledge. Bus master writes to the configuration register putting the DS620 in continuous conversion mode: 1SHOT = 0. DS620 generates acknowledge. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Master sends START CONVERT command to DS620 to start temperature conversions. DS620 generates acknowledge bit and begins conversions. Bus master generates a repeated start condition. Bus master sends DS620 address, R/W = 0. DS620 generates acknowledge. Master sends COPY DATA command to DS620 to copy data in from SRAM memory to EEPROM memory. DS620 generates acknowledge. Bus master sends STOP condition to end communication with DS620. (The bus master could send a repeated start condition if additional communication with the DS620 is desired.) SEQUENCE NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
15 of 15